“One Patient, One Surface”®
Reducing patient transfers can increase patient throughput while helping decrease the likelihood of incurring costs associated with staff injury.
The T3’s 90º rotating seat allows patients to remain seated for both lateral and A/P imaging. It is the preferred chair used for modified barium swallow studies and video fluoroscopy. Powered back, leg, and height adjustments provide effortless conversion from procedure chair to transport device.
The T3’s 90º rotating seat allows patients to remain seated for both lateral and A/P imaging. It is the preferred chair used for modified barium swallow studies and video fluoroscopy. Powered back, leg, and height adjustments provide effortless conversion from procedure chair to transport device.
Request a QuoteMeasurements & Dimensions
Specifications | T3-B (auto-extending footrest) | T3-FB (folding footrest) | T3-SB (short wheelbase) |
---|---|---|---|
Wheelbase (length x width) | 30” x 20” 76.20 cm x 50.80 cm |
30” x 20” 76.20 cm x 50.80 cm |
26” x 20” 66.04 cm x 50.80 cm |
Weight Capacity | 350 lbs. / 158.76 kg | 350 lbs. / 158.76 kg | 350 lbs. / 158.76 kg |
Seat Height (low ◆ high) | 25” ◆ 33” 63.50 cm ◆ 83.80 cm |
25” ◆ 33” 63.50 cm ◆ 83.80 cm |
25” ◆ 33” 63.50 cm ◆ 83.80 cm |
Back Width (no extension ◆ optional extension) | 15” ◆ 25” 38.10 cm ◆ 63.50 cm |
15” ◆ 25” 38.10 cm ◆ 63.50 cm |
15” ◆ 25” 38.10 cm ◆ 63.50 cm |
Side Rail Height (up, seat pan to rail top) ◆ Length | 10.5” ◆ 22” 26.70 cm ◆ 55.90 cm |
10.5” ◆ 22” 26.70 cm ◆ 55.90 cm |
10.5” ◆ 22” 26.70 cm ◆ 55.90 cm |
Overall Chair Height (low ◆ high) | 56” ◆ 64” 142.20 cm ◆ 162.60 cm |
56” ◆ 64” 142.20 cm ◆ 162.60 cm |
56” ◆ 64” 142.20 cm ◆ 162.60 cm |
Seat Width | 24” / 61 cm | 24” / 61 cm | 24” / 61 cm |
Overall Width (rails up ◆ rails down) | 31” ◆ 28.5” 78.70 cm ◆ 72.30 cm |
31” ◆ 28.5” 78.70 cm ◆ 72.30 cm |
31” ◆ 28.5” 78.70 cm ◆ 72.30 cm |
Patient Surface Length (standard ◆ with optional manual folding footrest) | 77” 196 cm |
71” 180 cm |
77” ◆ 71” 196 cm ◆ 180 cm |
Backrest Articulation Range | 0° – 90° | 0° – 90° | 0° – 90° |
Charging System Input Volts | 120 – 240 VAC | 120 – 240 VAC | 120 – 240 VAC |
Charging System Current | 350 mA | 350 mA | 350 mA |
Charging System Frequency | 50/60 Hz | 50/60 Hz | 50/60 Hz |
Charging System Max Power | 38.5 W | 38.5 W | 38.5 W |
Standard Features
Accessories
Common Procedures
Fabric & Finishes
Videos & Support Assets
Reducing patient transfers can increase patient throughput while helping decrease the likelihood of incurring costs associated with staff injury.
In the seated position, T-Series Procedure Chairs require half the space of a traditional stretcher and are easy to navigate through hallways, elevators and other close quarters. Plus, the small footprint frees-up floor space so additional units can be stored more efficiently.